Determining pipeline Viability for hydrogen blends
Read the associated technical paper “Fracture Toughness Evaluation of Vintage and Modern Thin-Walled Carbon Steel Pipelines for Hydrogen-Blended Natural Gas Service in Gas Distribution Networks.”
Existing steel distribution pipelines may be viable candidates for hydrogen-blended natural gas service, but operators need evidence showing how their materials respond when exposed to hydrogen.
C-FER evaluated thin-walled carbon steel distribution pipe installed between 1952 and 1997. Every material location tested showed lower fracture toughness in a 30% hydrogen–70% methane blend than in air. At the same time, vintage and modern materials produced fracture-toughness values within a similar range under hydrogen exposure, indicating that newer manufacturing practices did not automatically provide greater resistance to hydrogen-assisted fracture.
What information do operators need to determine if existing infrastructure is suitable for hydrogen blending?
When considering hydrogen blending or conversion, existing infrastructure may be suitable, but the decision must be supported by system-specific material testing and integrity assessment.
Fracture Toughness Connects Material Testing to Integrity Decision
Fracture toughness describes a material’s ability to resist crack initiation and extension. It is particularly important when evaluating hydrogen compatibility because hydrogen can reduce a steel’s resistance to crack propagation.
Fracture toughness provides a key input for flaw-stability and fitness-for-service assessments used to determine whether a pipeline section can remain in service, requires monitoring, or should be repaired or replaced.
Distribution Pipelines Need Distribution-Specific Evidence
Most available hydrogen pipeline research focuses on transmission systems, which typically operate at higher pressures and use thicker-wall and sometimeshigher-strength steels. Distribution networks are different. They generally operate at lower pressures and contain thinner-wall, sometimes lower-grade materials.
Hydrogen compatibility depends on several interacting factors, including:
- Operating stress and pressure
- Hydrogen partial pressure
- Steel grade and strength
- Material microstructure
- Weld type and condition
- Existing flaw characteristics
Because thin-walled distribution materials have historically been under-represented in hydrogen research, there is limited data specific to the materials commonly found in these pipeline systems.
Building Evidence from Vintage and Modern Pipe
C-FER evaluated eight thin-walled distribution pipeline materials installed between 1952 and 1997. Testing included parent metal, weld metal and heat-affected zones under both air and a 30% hydrogen–70% methane blend.
Additional mechanical, chemical and microstructural evaluations were completed to understand how material characteristics influenced performance and to provide data suitable for integrity assessments.
Hydrogen Changed How the Materials Resisted Cracking
The testing identified several findings relevant to integrity and hydrogen-conversion decisions:
- Fracture toughness decreased in hydrogen. Every material location tested showed lower toughness in hydrogen than in air.
- Newer was not automatically better. Vintage and modern steels exhibited fracture-toughness values within a similar range under hydrogen exposure, indicating that improvements that enhance toughness in air do not necessarily improve hydrogen resistance.
- Weld type mattered. Girth welds generally performed better than the corresponding parent material, while seam welds often showed lower fracture toughness and may warrant additional attention during hydrogen compatibility assessments.
- Localized brittle features mattered more than age alone. Certain impurities and brittle microstructural features were associated with reduced fracture toughness in both air and hydrogen.
These findings reinforce the importance of evaluating parent metal, seam welds and girth welds separately when assessing hydrogen compatibility.
What the Results Mean for Operators
The results do not provide blanket approval for all distribution systems being considered for conversion to hydrogen service. Instead, they provide a blueprint for how distribution systems should be evaluated before introducing hydrogen.
For operating companies, representative fracture-toughness data can support:
- Fitness-for-service and flaw-stability assessments
- Evaluation of existing cracks and weld-related features
- Repair, replacement or continued-service decisions
- Development of material sampling and testing plans
- Quantitative integrity and risk assessments
- Technical discussions with regulators and internal reviewers
The practical opportunity is to move beyond two assumptions: that existing infrastructure is automatically unsuitable for hydrogen, or that successful natural gas service guarantees hydrogen compatibility. A structured assessment provides the evidence needed to determine where existing assets may remain suitable and where additional investigation is required.
How C-FER Helps Operators
C-FER helps natural gas distribution and transmission operators evaluate how pipeline materials may respond to hydrogen and hydrogen-blended service.
C-FER can help operators:
- Develop representative sampling strategies
- Conduct fracture-toughness testing in hydrogen environments
- Evaluate pipe-body, seam-weld and girth-weld materials
- Characterize chemistry, hardness and microstructure
- Generate inputs for integrity and flaw-stability assessments
- Support hydrogen-blending and conversion decisions
C-FER’s hydrogen testing systems and specialized thin-wall testing capabilities allow material behaviour to be evaluated under conditions representative of proposed service. C-FER can provide operators with the evidence needed to understand compatibility risks, support integrity decisions and evaluate the suitability of existing infrastructure for future hydrogen service.
Contributor
Mark Cuglietta, PhD, PEng
Senior Engineering Specialist
Mark Cuglietta is a Senior Engineering Specialist at C-FER Technologies, an applied research company in Edmonton.
Mark has conducted and managed research and testing projects involving sulfide stress corrosion, hydrogen embrittlement, well design and simulation, downhole tools, and industrial processes. He has also completed sour service consultations and test designs for atypical or fit-for-purpose applications, participated in well simulation projects, including comprehensive permafrost thaw modelling, thermal hydraulic wellbore modelling (including conductive and free- and forced-convection heat transfer modelling), and structural modelling and analysis of downhole systems.